X-Ray Lead Glass
Lead glass for observation windows in CT, DR and X-ray rooms. Supplied to match the shielding value of the surrounding wall.
View Details
Lead-lined radiation protection doors are steel doors with an integrated lead core for CT, DR and X-ray rooms, made to the shielding value calculated for the room rather than to a fixed catalogue leaf.
A lead-lined radiation protection door is a steel door built around a lead core, fitted at the opening of a room that has to hold radiation inside it. The door is not chosen from a catalogue thickness — it is made to the lead equivalent value calculated for the room, so the shielding is continuous from the wall, across the frame and through the leaf.
These doors are used at CT scanning rooms, DR and X-ray rooms, interventional and angiography rooms, radiotherapy rooms, nuclear medicine rooms and veterinary imaging rooms — anywhere the room boundary is part of the shielding design rather than just a partition.
The lead core sits inside the leaf and is matched to the wall value, and the frame detail carries the shielding around the opening so there is no unshielded line at the junction between wall and door. Where staff need to see into the room, a lead glass vision panel is fitted with the same lead equivalent as the leaf, so the window does not become the weak point in the room boundary.
Selection starts from the room's shielding requirement and the door schedule: the lead equivalent, the opening size and the direction of travel. Manual or automated operation follows from the workflow — an angiography room with a heavy workload is worked differently from an X-ray room used occasionally.
| Product Type | Lead-lined door for radiation-shielded rooms |
|---|---|
| Typical Use | CT, DR, X-ray, interventional, radiotherapy and nuclear medicine rooms |
| Lead Equivalent | 1–3 mmPb, matched to the surrounding wall shielding |
| Leaf Configuration | Single leaf or double leaf |
| Clear Passage Width | 900–1,500 mm single leaf; 1,400–2,400 mm double leaf, customizable |
| Door Height | 2,100–2,400 mm, customizable |
| Leaf Thickness | 40–60 mm, set by the lead core and hardware detail, customizable |
| Operation | Manual swing, or automatic sliding / swing |
| Vision Panel | Lead glass, optional, at the same lead equivalent as the leaf |
| Frame | Steel frame with shielding continued around the opening |
| Finish | Powder-coated steel |
| Hardware | Handle, closer, lock and stop options |
| Packing | Plywood case with the leaf braced for transport |
| Notes | Values shown are typical of this door type. Final specification is confirmed against the room's shielding requirement. |
| Lead equivalent | 1–3 mmPb, matched to the wall shielding calculated for the room |
|---|---|
| Leaf configuration | Single or double leaf, to suit the opening and the equipment passing through |
| Clear passage width | Single leaf 900–1,500 mm; double leaf 1,400–2,400 mm, made to the project's structural opening |
| Door height | 2,100–2,400 mm, made to the opening height |
| Operation | Manual swing, automatic sliding, or automatic swing |
| Vision panel | Lead glass panel at the same lead equivalent as the leaf, sized to the sightline required |
| Frame | Steel frame with the shielding continued around the opening |
| Hardware | Handle, closer, lock and stop options to the access requirement |
| Finish | Powder-coated steel in the project's colour |
| Packing | Plywood case with the leaf braced; frame labelled by opening |
Lead-lined radiation protection doors are specified at the entrances to rooms where the boundary forms part of the shielding design: CT scanning rooms, DR and digital radiography rooms, X-ray examination rooms, interventional and angiography rooms, radiotherapy rooms, nuclear medicine rooms and veterinary imaging rooms. The door is selected from the room's shielding requirement and the door schedule, and its lead equivalent is normally kept the same as the surrounding wall so that the opening is not the weakest point in the room.






Every unit passes the same five stages below. Checks are recorded per unit rather than sampled, and a unit does not move to the next stage until the previous one is signed off.
Lead sheet thickness, barium sulphate density and glass lead equivalent are verified against the supplier certificate before the material enters the workshop.
Shielding layers are measured for thickness and uniformity at the points that matter most — corners, edges and any joint. This is the check that decides whether the product is fit to ship.
Overlaps and joints are inspected for width and continuity. A gap in a shield is not a cosmetic defect, so every joint is measured rather than sampled.
Frame, glass and shielding are checked for fit and alignment. Doors and screens are operated through their full range to confirm the shielding stays continuous in the closed position.
Surfaces and edges are inspected for damage and finish quality, then the unit is protected, labelled with its shielding data and packed against the shipping list.
The leaf is braced inside a plywood case so it stays true in transit, with the frame and hardware packed separately and labelled.






How do we know which lead equivalent to order?
It comes from the shielding calculation for the room, which follows the equipment, the workload and the room's layout. The door is then made to that value rather than chosen from a list.
Can the door's lead equivalent be different from the wall?
It can, but it is normally kept the same. Matching the wall avoids the entrance becoming the point where the room is easiest to penetrate.
Is the shielding continuous around the frame?
Yes. The frame detail carries the lead around the opening so there is no unshielded line where the wall meets the door.
What about the vision panel?
A lead glass panel is fitted at the same lead equivalent as the leaf. Where the sightline needs a large panel, that influences the leaf design rather than being decided afterwards.
Manual or automatic — which is better?
It follows from the department's workload. Rooms with steady traffic and staff carrying equipment are usually automated; rooms used occasionally are normally manual.
How heavy does the door get?
A lead core adds weight, so the leaf weight, hinges and closer are set together. It is one reason the door is made to the opening rather than selected from a standard size.
Can it be used on a room with a mobile imaging unit?
Yes. The shielding value is calculated for the actual use of the room, so a room with mobile equipment is shielded for that workload.
What do you need from us to quote?
The room's shielding requirement, the door schedule and opening sizes, the wall build-up, and whether the door is to be manual or automatic.
Background reading on Lead-Lined Radiation Protection Doors and how it is specified.
A lead-lined door has to match the wall's shielding value and carry it across the opening. This article covers the lead core, the frame detail and when to add a lead glass vision panel.
Read ArticleTwo quotations for the same doors and shielding are rarely priced on the same scope. This article sets out what to align before comparing figures, and which differences change the cost on site.
Read ArticleAn observation window carries the same lead equivalent as the wall it sits in, and its thickness depends on how far the operator stands back. This article covers what to plan before ordering.
Read Article
Tell us the room type, opening size, lead equivalent requirement or door configuration. We will come back with a practical supply proposal.