Electrolytic Steel Plates
Electrolytically coated steel panels used as the wall and ceiling skin in operating room and cleanroom construction.
View Details
Modular operating room panels are prefabricated wall panels that build a theatre or cleanroom as a system, giving a flat, easy-clean surface with the joints, corners and service openings detailed as part of the panel.
A modular operating room panel is a prefabricated wall element that builds a theatre or cleanroom as a system rather than as a built wall with a finish applied to it. The panel arrives with its face, core and edge detail already made, so the room is assembled to a module rather than finished on site.
Modular panels are used for operating theatres, hybrid and interventional theatres, cleanrooms and controlled production areas, pharmaceutical and medical device production rooms, laboratories, and preparation and clean utility rooms. They are chosen where a room has to be built to a controlled standard, or where the wall may need to change later.
Each panel carries its own edge detail, so the joints between panels are formed details rather than a sealant line. Service openings, sockets, gas outlets and equipment rails are set out in the panel module, which means the services are planned with the wall instead of being cut into a finished surface. Because the wall is a system of panels, it can be taken down and reinstalled when a room changes use, and the panels can be re-used rather than replaced — which is the practical difference between a modular room and a built one.
Selection follows the room's dimensions, the services it has to carry and the finish required. The panel module is set out with the door and the ceiling so that the whole room works to one grid.
| Product Type | Prefabricated wall panel system for theatres and cleanrooms |
|---|---|
| Typical Use | Operating theatres, cleanrooms and controlled production areas |
| Panel Width | 900–1,200 mm, customizable |
| Panel Height | 2,400–3,000 mm, customizable |
| Panel Thickness | 50–100 mm, customizable |
| Face Material | Coated steel, stainless steel or glass, to the project |
| Core | Insulated or honeycomb core, selected with the panel system |
| Joints | Formed edge detail between panels |
| Surface | Flat, smooth, easy-clean face |
| Service Integration | Openings for sockets, gas outlets and equipment rails set out in the module |
| Packing | Crated by room or elevation, labelled for assembly |
| Notes | Values shown are typical of this system. Final specification is confirmed against the room layout and the services it carries. |
| Panel width | 900–1,200 mm, set by the room's module |
|---|---|
| Panel height | 2,400–3,000 mm, made to the room height |
| Panel thickness | 50–100 mm, selected with the core and the services in the wall |
| Face material | Coated steel, stainless steel, or glass, per the room |
| Colour | Supplied in the project's colour |
| Core | Insulated core, or honeycomb core, selected with the system |
| Service integration | Openings for sockets, gas outlets, equipment rails and data set out in the module |
| Corner and junction details | Formed internal and external corners, and junctions to door frames |
| Layout | Panel module set out with the door and ceiling grid for the room |
| Packing | Crated by room or elevation, labelled for site assembly |
Modular operating room panels are used where a controlled room is built as a system: operating theatres, hybrid and interventional theatres, cleanrooms and controlled production areas, pharmaceutical production rooms, medical device assembly areas, laboratories and research areas, and clean utility or preparation rooms. They are also chosen where the room may change use, since the wall can be taken down and re-erected. The panel is selected from the room dimensions, the services the wall has to carry and the finish required, and the module is set out with the door and ceiling so that everything works to the same grid.






Every unit passes the same five stages below. Checks are recorded per unit rather than sampled, and a unit does not move to the next stage until the previous one is signed off.
Steel grade, panel core, lighting components and electrical parts are checked against the specification and incoming inspection records.
Panels, frames and housings are cut and formed, then checked for dimensions, flatness and edge quality before assembly.
Panels and equipment are assembled and wired to the drawing. Wiring, fixing points and sealing between panels are inspected before the unit is closed up.
Every unit is powered and run: controls, travel and locking on tables; light output and field adjustment on lamps; electrical safety and earth continuity on wired products.
Clean finish, colour match and absence of surface defects are confirmed, and the unit is protected and packed with its test record and instructions.
Crated by room or elevation, labelled for assembly.






How is this different from building a wall and finishing it?
The panel arrives with its face, core and edge detail already made. The wall is assembled to a module, so there is no wet finishing and the joints are formed rather than sealed on site.
Why does the panel module matter?
Because the whole room is set out to it — panels, door openings, ceiling grid and services. If the module is set out with the door and ceiling, the room lines up; if not, it has to be made to work on site.
How are services handled in the wall?
Openings for sockets, medical gas outlets, rails and data are set out in the panel module, so the face is not cut into after the room is finished.
Can the wall be changed if the room's use changes?
Yes. The panels can be dismantled and reinstalled, and can be re-used rather than replaced. That is one of the main reasons a modular room is chosen over a built one.
What heights are available?
Panels typically run 2,400–3,000 mm, made to the room height, so the wall can reach the ceiling without a separate filling piece.
How thick are the panels?
Generally 50–100 mm, depending on the core and what has to be carried inside the wall.
Are the corners part of the system?
Yes. Internal and external corners, and the junctions to door frames, are formed details made to suit the panel system.
What do you need from us to quote?
The room dimensions and layout, the height and the services the wall has to carry, the face material and colour required, and the positions of doors and openings.
Background reading on Modular Operating Room Panels and how it is specified.
In a modular theatre, the wall module governs everything else in the room. This article explains how the grid is set out and what has to be agreed before the panels are manufactured.
Read ArticleDecisions in a healthcare fit-out depend on each other. This article sets out the order that avoids rework — from the shielding requirement and the wall build-up through to doors, ceilings and equipment.
Read ArticleA modular theatre wall is assembled to a grid rather than finished on site. This article explains how the panel module is planned with the door, the ceiling and the services.
Read Article
Tell us the room type, opening size, lead equivalent requirement or door configuration. We will come back with a practical supply proposal.