Operating Room Sealed Doors
Airtight door systems for operating theatres, with sealed gaskets and optional foot sensor or touchless activation.
View Details
Automatic sealed sliding doors are motorised hermetic door systems for operating theatres, cleanrooms and other controlled healthcare areas, giving hands-free entry with a gasket that compresses against the frame on closing.
An automatic sealed sliding door is a motorised leaf that runs on a track and closes against a gasket, so the room keeps the air regime it was designed around without staff having to touch the door. It is the standard choice wherever a controlled room carries steady two-way traffic and hands-free entry matters more than the lower cost of a manual leaf.
These doors are used at operating theatres, cleanrooms and controlled production areas, hybrid and interventional theatres, day surgery and procedure rooms, ICU and high-dependency units, pharmacy and preparation rooms, laboratories, and the corridors that lead into a controlled suite.
The leaf runs on a surface-mounted or concealed track, chosen to suit the wall build-up, and closes with a sealed action that compresses the gasket rather than simply meeting the frame. Activation is set to match the room: motion sensor where traffic is general, foot or touchless sensor where the leaf should not be handled, push plate where the opening is operator-controlled.
Selection follows the opening width, the traffic through it, and the room's air regime. Where two doors form a controlled passage, an interlocking arrangement can be supplied, and a manual release is provided so the door can still be operated during a power interruption. Door sets are made to the project's door schedule, with the leaf braced in the crate and the operator packed separately.
| Product Type | Motorised sealed sliding door |
|---|---|
| Typical Use | Operating theatres, cleanrooms and controlled healthcare areas |
| Operation | Automatic sliding, single or bi-parting |
| Leaf | Sealed leaf with compression gasket |
| Clear Passage Width | 900–1,500 mm single leaf; 1,400–2,400 mm bi-parting, customizable |
| Door Height | 2,100–2,400 mm, customizable |
| Leaf Thickness | 40–60 mm, customizable |
| Opening / Closing Speed | 200–600 mm/s, customizable |
| Opening / Closing Time | 2–20 s, customizable |
| Activation | Motion sensor, foot sensor, touchless sensor or push plate |
| Track | Surface-mounted or concealed, to suit the wall build-up |
| Closing | Sealed closing action, force set on site |
| Interlocking | Available where two doors form a controlled passage |
| Emergency Operation | Manual release for use during a power interruption |
| Finish | Powder-coated steel, cleanable surface |
| Power Supply | 220 V / 50 Hz or 110 V / 60 Hz |
| Packing | Crated with the leaf braced and the operator packed separately |
| Notes | Values shown are typical of this door type. Final specification is confirmed against the door schedule and the room's air regime. |
| Leaf arrangement | Single sliding leaf, or bi-parting pair on wider openings |
|---|---|
| Clear passage width | Single leaf 900–1,500 mm; bi-parting 1,400–2,400 mm, made to the project's structural opening |
| Door height | 2,100–2,400 mm, made to the project's opening height |
| Activation | Motion sensor, foot sensor, touchless sensor or push plate |
| Track | Surface-mounted or concealed, to suit the wall build-up |
| Opening and closing speed | 200–600 mm/s, set on the control board |
| Interlocking | Available where two doors form a controlled passage |
| Glazing | Vision panel, in the size the sightline requires |
| Finish | Powder-coated steel in the project's colour, or stainless steel where cleaning is aggressive |
| Power supply | 220 V / 50 Hz or 110 V / 60 Hz, to the project's power standard |
| Packing | Standard export crate; packing and marking adjusted to the project's shipping method |
Automatic sealed sliding doors are used wherever a controlled room carries regular two-way traffic and the door has to stay closed between movements: operating theatres and hybrid or interventional theatres, day surgery and procedure rooms, ICU and high-dependency units, cleanrooms and controlled production areas, pharmacy and medicine preparation rooms, laboratories and research areas, and the corridors that lead into a controlled suite. The door is selected from the opening width, the volume and type of traffic, and the air regime the room has to hold, and the same arrangement is normally carried across a department so that movement between rooms stays consistent.






Every unit passes the same five stages below. Checks are recorded per unit rather than sampled, and a unit does not move to the next stage until the previous one is signed off.
Panel gauges, frame profiles, seal gaskets and hardware are checked against the specification and the mill certificates that come with the material before it is released to production.
Sheet and frame are cut, punched and folded on jig-set equipment. First-off pieces are checked for door leaf size, opening cut-outs and diagonal tolerance before the batch runs.
Frame and leaf are welded and squared, then inspected for weld penetration, distortion and flatness. Leaf thickness and frame alignment are recorded per unit.
Gasket continuity, closing force and hardware operation are tested on the assembled door. Every door is opened, closed and latched through its full cycle at least once.
Surface coating, colour match and edge protection are inspected under even light. Doors are then protected, labelled and checked against the packing list before dispatch.
Supplied crated, with the leaf braced to stay true and the operator, track and controls packed separately and labelled.






What is the difference between this and an ordinary automatic sliding door?
The closing action. The leaf closes against a compression gasket so the room keeps its air regime, and the track and frame detail are built for that seal rather than for a general entrance.
Which activation should we choose?
It follows from how the room is used. Motion sensor suits general traffic, foot or touchless sensor where the leaf should not be handled, and a push plate where entry is controlled by staff.
What happens during a power interruption?
A manual release allows the leaf to be operated by hand, so the room is not left closed off.
Can it be bi-parting instead of single leaf?
Yes. Single or bi-parting is chosen from the opening width and the traffic. Wider openings are normally handled as a bi-parting pair, up to about 2,400 mm clear passage.
How fast does the door open and close?
Typically 200–600 mm/s, with the full opening or closing taking 2–20 s. Both are set on the control board during commissioning.
Can the track be concealed in the wall?
It can be surface-mounted or concealed, depending on the wall build-up. Concealed tracks need the ceiling or wall detail to be planned with the door.
Can two doors be interlocked?
Yes. Where doors form a controlled passage, an interlocking arrangement is supplied as part of the door set.
What do you need from us to quote?
The door schedule and the opening sizes, the wall build-up, the room's air regime, and the activation the department wants. From those we confirm the leaf arrangement, track and finishing detail.
Background reading on Automatic Sealed Sliding Doors and how it is specified.
Lead time on a healthcare package is set by five variables, not by the factory's size. This article explains which ones buyers control, and how to plan a programme around them.
Read ArticleA manual sealed door costs less and needs less maintenance; an automatic one removes handling. This article sets out the four questions that decide which a room should have.
Read Article