Radiation Protection Louvers

Radiation protection louvers are lead-lined ventilation louvers for X-ray and CT room doors and walls, letting air pass while keeping the shielding value continuous across the opening they serve.

  • Lead Equivalent1–2 mmPb, matched to the surrounding shielding
  • TypeDoor louver, or wall-mounted
  • Blade TypeAngled blades, lead-lined
  • Frame Size200 × 200 mm to 600 × 600 mm
  • Frame FinishPowder-coated steel
Radiation Protection Louvers — application overview

Overview

A radiation protection louver is a ventilation opening that keeps the shielding value of the surface it sits in. A shielded room still has to breathe — air has to move in and out of an X-ray or CT room — and every opening in a shielded boundary is a place where the value can be lost. The louver is the detail that lets the air through without doing that.

Louvers are used in the doors and walls of CT scanning rooms, DR and X-ray examination rooms, interventional and angiography rooms, radiotherapy and nuclear medicine rooms, and veterinary imaging rooms — wherever the room is ventilated and the boundary has to stay shielded.

Blades are angled and lead lined so that air passes between them while a direct line through the louver is blocked, and the frame carries the shielding into the surrounding wall or door leaf so there is no unshielded line at the edge of the opening. Door louvers are normally supplied with the door so that the leaf structure and the louver are detailed together rather than the opening being cut on site.

Selection follows the air volume that has to pass, the space available in the door or wall, and the shielding value of the surface. The louver is normally ordered with the door or the lining so that its value matches what it interrupts.

Specifications

Product TypeLead-lined ventilation louver
Typical UseDoors and walls of shielded rooms requiring ventilation
Lead Equivalent1–2 mmPb, matched to the surrounding shielding, customizable
TypeDoor louver, or wall-mounted
Blade TypeAngled blades, lead-lined
Frame Size200 × 200 mm to 600 × 600 mm, customizable
Blade PitchSet to give the required free area
Free AreaSuited to the air volume required by the room
FrameSteel frame carrying the shielding to the surrounding surface
FinishPowder-coated steel
PackingCrated; door louvers normally packed with the door set
NotesValues shown are typical of this item. Final specification is confirmed against the room's shielding and ventilation requirements.

Features

  • Ventilation without losing the value — Air passes between the blades while the shielding value of the surface is kept.
  • Angled lead-lined blades — The blade angle blocks a direct line through the louver, so the opening is not a clear path for radiation.
  • Frame carries the shielding — The frame takes the value into the surrounding wall or door leaf, so the edge of the opening is not left untreated.
  • Supplied with the door where possible — Door louvers are detailed with the leaf rather than cut into it on site, which keeps the leaf structure intact.
  • Size chosen from the air volume — The louver is selected from the air the room needs, not from a standard size that happens to fit.
  • Matched to its surface — The lead equivalent is set to the wall or door it interrupts, so the opening is not weaker than what surrounds it.

Available Customization

Lead equivalent1–2 mmPb, matched to the shielding of the door or wall
TypeDoor louver, or wall-mounted frame
Frame size200 × 200 mm to 600 × 600 mm, made to the opening and the air volume required
Blade pitchSet to give the free area the room's ventilation needs
Blade angleSet to block a direct line through the louver
FrameSupplied to suit the door leaf thickness, or the wall build-up
FinishPowder-coated steel in the project's colour
PackingCrated; packed with the door set where the louver is fitted to a leaf

Applications

Radiation protection louvers are used wherever a shielded room has to be ventilated and the boundary has to keep its value: the doors and walls of CT scanning rooms, DR and X-ray examination rooms, interventional and angiography rooms, catheterisation laboratories, radiotherapy and nuclear medicine rooms, and veterinary imaging rooms. They are also used at plant and service openings where air has to pass through a shielded surface. The louver is selected from the air volume required and the value of the surface it interrupts, and is normally ordered together with the door or lining so that the detail is planned as one item.

Radiation Protection Louvers — CT Scanning Room

CT Scanning Room

Radiation Protection Louvers — DR and Digital Radiography Room

DR and Digital Radiography Room

Radiation Protection Louvers — Industrial Radiography Area

Industrial Radiography Area

Radiation Protection Louvers — Radiotherapy Room

Radiotherapy Room

Radiation Protection Louvers — Nuclear Medicine Viewing Window

Nuclear Medicine Viewing Window

Radiation Protection Louvers — X-Ray Examination Room

X-Ray Examination Room

Manufacturing & Quality Control

Every unit passes the same five stages below. Checks are recorded per unit rather than sampled, and a unit does not move to the next stage until the previous one is signed off.

STEP 01

Incoming Material

Lead sheet thickness, barium sulphate density and glass lead equivalent are verified against the supplier certificate before the material enters the workshop.

STEP 02

Lead Equivalent Verification

Shielding layers are measured for thickness and uniformity at the points that matter most — corners, edges and any joint. This is the check that decides whether the product is fit to ship.

STEP 03

Joint & Overlap Inspection

Overlaps and joints are inspected for width and continuity. A gap in a shield is not a cosmetic defect, so every joint is measured rather than sampled.

STEP 04

Assembly Check

Frame, glass and shielding are checked for fit and alignment. Doors and screens are operated through their full range to confirm the shielding stays continuous in the closed position.

STEP 05

Finish & Dispatch

Surfaces and edges are inspected for damage and finish quality, then the unit is protected, labelled with its shielding data and packed against the shipping list.

Packaging & Delivery

Crated; door louvers normally packed with the door set.

Plywood case
Plywood case
Protective packing
Protective packing
Product labelling
Product labelling
Export packing
Export packing
Loading
Loading
Customized packing
Customized packing

FAQ

Why does a shielded room need a louver at all?

The room has to be ventilated. Air has to move in and out, and the louver is the detail that allows that without opening a gap in the shielding.

How does a louver keep the value if air passes through it?

The blades are angled and lead lined. Air passes at an angle between them, while a direct line through the opening is blocked by the blade geometry and the lining.

Which lead equivalent should the louver have?

The same as the surface it sits in — the door leaf or the wall. The opening should not be the weakest point of the boundary.

Should the louver be ordered with the door?

Where it is fitted to a door leaf, yes. It is then detailed with the leaf structure rather than cut in on site, which keeps the leaf and its shielding intact.

How is the louver size decided?

From the air volume the room requires. The free area needed sets the frame size, which then has to fit the door or wall available.

Can it be fitted into an existing shielded wall?

Yes, provided the surrounding shielding is detailed to meet the louver frame so the value is continuous at the edge of the opening.

Does a louver block all radiation?

No opening can be treated as perfect, which is why the value is matched to the surface and the blade geometry is set to block a direct line. The louver is designed as part of the room's shielding, not as a stand-alone barrier.

What do you need from us to quote?

The air volume the room requires, the size available in the door or wall, the value of the surrounding shielding, and whether the louver is to be fitted to a door leaf or a wall.

Related Articles

Background reading on Radiation Protection Louvers and how it is specified.

Radiation Protection11 October 2025166 views

Designing a Lead-Lined Room for a CT Scanner

A CT room is shielded as one boundary, not wall by wall. This article covers how the lead equivalent is set and how the lining, door, window and penetrations are detailed to match it.

Read Article

View All Articles

Send Us Your Project Requirements

Tell us the room type, opening size, lead equivalent requirement or door configuration. We will come back with a practical supply proposal.

Email