Operating Room Sealed Doors
Airtight door systems for operating theatres, with sealed gaskets and optional foot sensor or touchless activation.
View Details
Steel cleanroom doors are flush-faced, sealed door systems built around the cleanroom wall panel system on the project, giving a controlled close and a cleanable finish for pharmaceutical, electronics and laboratory environments.
A steel cleanroom door is a flush-faced leaf and a sealed frame made to match the cleanroom wall panel system the room is built from. The door is not a separate item bought alongside the wall — the frame profile, the fixing detail and the sealing line all follow from the panel system, which is why the wall build-up has to be known before the door is made.
These doors are used in pharmaceutical production areas, electronics and precision manufacturing cleanrooms, food and beverage controlled areas, hospital clean utility and storage rooms, laboratory and research areas, medical device production areas, and the airlocks and change rooms that lead into them.
The leaf is flush faced with no ledges where dust or cleaning fluid can collect, and the finish is cleanable across the whole surface. A perimeter gasket gives a controlled close, and a vision panel can be added in glass or double glazing where staff need to see into the room before entering. Operation is manual swing or automatic, depending on the room's traffic and the class it is held to.
Selection follows the panel system, the cleanroom class and the opening size. Certain rooms are supplied to suit the wall thickness the panels give, so the frame arrives ready to fix rather than to be packed out on site.
| Product Type | Sealed door for cleanroom and controlled-environment areas |
|---|---|
| Typical Use | Cleanrooms built on a panel wall system |
| Leaf | Flush-faced steel leaf |
| Frame | Sealed frame profiled to suit the wall panel system |
| Clear Passage Width | 800–1,500 mm single leaf; 1,200–2,400 mm double leaf, customizable |
| Door Height | 2,100–2,400 mm, customizable |
| Leaf Thickness | 40–60 mm, customizable |
| Operation | Manual swing, or automatic |
| Sealing | Perimeter gasket |
| Vision Panel | Glass or double-glazed, optional |
| Finish | Powder-coated steel, cleanable surface |
| Hardware | Closer, handle, and lock options |
| Packing | Plywood case with the leaf braced and frame labelled |
| Notes | Values shown are typical of this door type. Final specification is confirmed against the project's panel system and cleanroom class. |
| Frame profile | Made to the project's cleanroom panel system and wall thickness |
|---|---|
| Leaf configuration | Single or double leaf |
| Clear passage width | Single leaf 800–1,500 mm; double leaf 1,200–2,400 mm, made to the project's structural opening |
| Door height | 2,100–2,400 mm, made to the opening height |
| Operation | Manual swing, or automatic with motion, foot or touchless activation |
| Glazing | Clear glass or double-glazed vision panel, sized to the sightline required |
| Hardware | Closer, handle and lock options to the access requirement |
| Finish | Powder-coated steel in the project's colour, or stainless steel where cleaning agents are aggressive |
| Sealing | Perimeter gasket, with the profile set to the cleanroom class |
| Packing | Plywood case, frame labelled by opening for site identification |
Steel cleanroom doors are specified wherever a controlled room is built on a panel wall system and the opening has to hold the same conditions as the wall: pharmaceutical production areas, electronics and precision manufacturing cleanrooms, food and beverage controlled areas, hospital clean utility and storage rooms, laboratory and research areas, medical device production areas, cleanroom airlocks and change rooms, and optical or precision assembly rooms. The door is selected from the panel system, the cleanroom class and the opening size, and is normally carried through a suite so that every opening in the room matches.






Every unit passes the same five stages below. Checks are recorded per unit rather than sampled, and a unit does not move to the next stage until the previous one is signed off.
Panel gauges, frame profiles, seal gaskets and hardware are checked against the specification and the mill certificates that come with the material before it is released to production.
Sheet and frame are cut, punched and folded on jig-set equipment. First-off pieces are checked for door leaf size, opening cut-outs and diagonal tolerance before the batch runs.
Frame and leaf are welded and squared, then inspected for weld penetration, distortion and flatness. Leaf thickness and frame alignment are recorded per unit.
Gasket continuity, closing force and hardware operation are tested on the assembled door. Every door is opened, closed and latched through its full cycle at least once.
Surface coating, colour match and edge protection are inspected under even light. Doors are then protected, labelled and checked against the packing list before dispatch.
Packed in plywood cases with the frame and leaf separated and labelled, so the correct door reaches the correct opening on site.






Why do you need to know our panel system before making the door?
The frame profile, fixing detail and sealing line all follow from the wall the door sits in. Making the door to the panel system is what avoids packing out the opening on site.
Can the door be fitted into an existing cleanroom wall?
Yes, provided the panel system and wall thickness are known. The frame is then made to suit that build-up.
Is the leaf really flush, or does it have a raised edge?
It is flush faced. A flat surface is what keeps dust and cleaning fluid from collecting in ledges.
What finish is used, and can it be stainless instead?
Powder-coated steel as standard, in the project's colour. Stainless steel is used where cleaning agents are aggressive.
Do we need a vision panel?
It is optional. Single glass or double glazing can be fitted where staff need to see into the room before entering.
Manual or automatic — which do we need?
Manual swing suits rooms with occasional use. Automatic is chosen where traffic is steady or where the leaf should not be handled.
How wide can the opening be?
Single leaf from about 800 mm to 1,500 mm; double leaf from about 1,200 mm up to 2,400 mm clear passage.
What do you need from us to quote?
The panel system and wall thickness, the door schedule and opening sizes, the cleanroom class, and whether the door is to be manual or automatic.
Background reading on Steel Cleanroom Doors and how it is specified.
Powder-coated steel and stainless steel behave differently under hospital cleaning routines. This article explains how to choose a door finish from the cleaning agents and the traffic a room actually sees.
Read ArticleLead time on a healthcare package is set by five variables, not by the factory's size. This article explains which ones buyers control, and how to plan a programme around them.
Read ArticleMost quotation delays are caused by missing drawings, not by slow suppliers. This article lists the drawings and schedules that turn an enquiry into a firm offer for doors, shielding and equipment.
Read Article
Tell us the room type, opening size, lead equivalent requirement or door configuration. We will come back with a practical supply proposal.